NZS Nuclear Density Testing Workflows

NZS Nuclear Density Testing Workflows

QEST Platform 4.92 and 4.93
Applies to QESTField Tests


This article covers the data entry process for entering test results related to:

  • NZS 4407:2015 Test 4.2 the field water content and field dry density of compacted materials - direct transmission.
  • NZS 4407:2015 Test 4.3 the field water content and field dry density of compacted materials - backscatter mode.

Contents

Overview 

The data entry process in QESTField for NZS 4407:2015 Test 4.2 and NZS 4407:2015 Test 4.3 is composed of a single-page workflow per shot of field density testing. This article will discuss how to add and complete data entry for a point of testing.


Data Entry

Setup

Refer to the Setup Section article for details on how to set the values on this section. 


Sample Details 

The sample details section provides fields for entering general information about the sampling process and material details for 2 scenarios:

  1. With Relative Compaction 
  2. Without Relative Compaction

With Relative Compaction

Workflows that import a reference density value will not have fields to enter material details on the "Sample Details" section. Instead, the material details will be copied from the reference density sample. Most NZS QESTField workflows do import a reference density.

Field Prompt
Expected Information
Sample IDAn automatically generated identifier for this test point and any material sampled from the location.
Container/Field Sample ID

Used to record where more than one container is used to collect a sample. If multiple containers are used, all relevant IDs should be recorded here.

TRNA Test Request Number (if one exists or is available) can be entered here if a different number needs to be used for each sample. Otherwise the work order level TRN field should be set in QESTLab.
Client Sample IDIf the client has a sample number by which they would like to refer to this sample, it should be entered here.
Sampled ByThe name of the tester and sampler. Automatically set to the name of the currently logged in user.
Date Sampled

The date of the test, automatically populated from today's date of the device being used. 

Important

Since today's date is automatically populated when entering this data, care should be taken when performing data entry for previous days' work since this date will need to be manually adjusted for every point of testing on that work order.

Time Sampled

The date of the test, automatically populated from the current time of the device being used. 

Important

Since the time is automatically populated when entering this data, care should be taken when performing data entry for previous days' work since this date will need to be manually adjusted for every point of testing on that work order.

Sampling Method

The sampling method applicable to the sample being taken. Options available here come from the Sampling Method list populated in QESTLab. 

If the free entry option is enabled on this list by a system administrator via the QEST Administrator Console, the setting will be honored by QESTField Tests.

Without Relative Compaction 

The workflow "Nuclear Density [NZS 4407:2015 Test 4.2] (No Relative Compaction)" does not include a relative compaction test and does not allow the importing of a reference density value. Therefore the "Sample Details" section will have additional fields for data entry for this workflow. More details on this scenario is explained in 1067221041.

Test Location

Refer to the Setup Section article for details on how to enter location values.


Reference Density for Relative Compaction

Workflows that contain a relative compaction test for NZS 4407: 2015 Test 4.2 and Test 4.3 allow the import of a reference density value. See the Importing a Laboratory Reference Density article for more information. The only workflow that does not allow the import of a reference density is "Nuclear Density [NZS 4407:2015 Test 4.2] (No Relative Compaction)".

Field Density Test

This section allows the user to enter the test data relevant to the both NZS field density tests:

Field Density section for NZS 4407:2015 Test 4.2 

Field Prompt
Expected Information
Density GaugeThe density gauge used for the test, from QESTLab's equipment register.
DSThe field density standard count.
MSThe field moisture standard count.
Probe Depth (mm)The depth of the nuclear density probe.
Test Density CountThe density count at the test site from the gauge.
Test Moisture CountThe moisture count at the test site from the gauge.
Wet Density (t/m³)The wet density value read directly from the gauge.
Moisture Content (%)The moisture content value read directly from the gauge.
Moisture Correction FactorImports from Moisture content correction factor document on work order (if exists). Displays the same value as in the setup section.
Corrected Moisture Content (%)Calculated by multiplying the field Moisture Content by the Moisture Correction Factor
Dry Density (t/m³)The dry density value read directly from the gauge.

Field Density section for NZS 4407:2015 Test 4.3

Important

The field prompts for this section are identical his identical to the field density section for NZS 4407:2015 Test 4.2 expect there is no probe depth due to it being a backscatter test. 


Relative Compaction 

When a reference density is defined on a workflow, it is possible to calculate results in the field. By pressing the Calculate button after completing data entry, the user can review the results of the test. This section is not available in the "Nuclear Density [NZS 4407:2015 Test 4.2] (No Relative Compaction)" workflow. 


Available Workflows

There are four alternative workflows for the NZS 4407:2015 Test 4.2 test method, as listed below.

Variant
Behaviour
Nuclear Density [NZS 4407:2015 Test 4.2] Adds a relative compaction test to the sample as the reference density test to be completed at the laboratory as well as the appropriate test reports. 
Nuclear Density [NZS 4407:2015 Test 4.2] (Lab Moisture)Adds a moisture content test and relative compaction test to the sample as the reference density test to be completed at the laboratory as well as the appropriate test reports. 
Nuclear Density [NZS 4407:2015 Test 4.2] (Lab Moisture/Lot Conformity)Adds a moisture content test and relative compaction test to the sample as the reference density test to be completed at the laboratory as well as a lot conformity test to the work order along with the appropriate test reports. 
Nuclear Density [NZS 4407:2015 Test 4.2] (No Relative Compaction)Does not allow import of a reference density test or calculate results based on that reference density test. 


There are four alternative workflows for the NZS 4407:2015 Test 4.3 test method, as listed below.

Variant
Behaviour
Nuclear Density [NZS 4407:2015 Test 4.3] Adds a relative compaction test to the sample as the reference density test to be completed at the laboratory as well as the appropriate test reports. 
Nuclear Density [NZS 4407:2015 Test 4.3] (Lot Conformity)Adds a relative compaction test to the sample as the reference density test to be completed at the laboratory as well as a lot conformity test to the work order along with the appropriate test reports. 
Nuclear Density [NZS 4407:2015 Test 4.3] (Lot Conformity/Moisture Correction)Adds a relative compaction test to the sample as the reference density test to be completed at the laboratory. A moisture content correction factor test and lot conformity test is added to the work order as well as the appropriate test reports. 
Nuclear Density [NZS 4407:2015 Test 4.3] (Moisture Correction)Adds a relative compaction test to the sample as the reference density test to be completed at the laboratory as well as a work order level moisture content correction factor test along the appropriate test reports. 

Additional Cases 

Sample Details Section for Workflows Without Relative Compaction 

The Sample Details section includes additional fields for data entry when the workflow "Nuclear Density [NZS 4407:2015 Test 4.2] (No Relative Compaction)" is selected. 

Field Prompt
Expected Information
Sample IDAn automatically generated identifier for this test point and any material sampled from the location.
Container/Field Sample ID

Used to record where more than one container is used to collect a sample. If multiple containers are used, all relevant IDs should be recorded here.

TRNA Test Request Number (if one exists or is available) can be entered here if a different number needs to be used for each sample. Otherwise the work order level TRN field should be set in QESTLab.
Client Sample IDIf the client has a sample number by which they would like to refer to this sample, it should be entered here.
Sampled ByThe name of the tester and sampler. Automatically set to the name of the currently logged in user.
Date Sampled

The date of the test, automatically populated from today's date of the device being used. 

Important

Since today's date is automatically populated when entering this data, care should be taken when performing data entry for previous days' work since this date will need to be manually adjusted for every point of testing on that work order.

Time Sampled

The date of the test, automatically populated from the current time of the device being used. 

Important

Since the time is automatically populated when entering this data, care should be taken when performing data entry for previous days' work since this date will need to be manually adjusted for every point of testing on that work order.

Sampling Method

The sampling method applicable to the sample being taken. Options available here come from the Sampling Method list populated in QESTLab. 

If the free entry option is enabled on this list by a system administrator via the QEST Administrator Console, the setting will be honored by QESTField Tests.

SourceGeneral source of the material under test. Options available here come from the Agg/Soil Material Source list populated in QESTLab. 
Material

General description of the material or product under test, applicable to all samples on the work order. Options available here come from the Agg/Soil Materials list populated in QESTLab. 

If the free entry option is enabled on this list by a system administrator via the QEST Administrator Console, the setting will be honored by QESTField Tests.

Soil DescriptionA soil description specific to the current sample.


Products described on these pages, including but not limited to QESTLab®, QESTNet, QESTField, Construction Hive, and associated products are Trademarks () of Spectra QEST Australia Pty Ltd and/or related companies.

The content of this page is confidential. Do not share, duplicate or distribute without permission.

© 2020 Spectra QEST® Australia Pty Ltd and/or related companies.  Terms of Use and Privacy Statement


Integrity | Curiosity | Empathy | Unity

The content of this page is confidential and for internal Spectra QEST use only. Do not share, duplicate or distribute without permission.